Troubleshooting
Answers to common questions and problems. If your issue is not covered here, contact us and we will help.
The status LED blinks a code
In normal operation the LED rests at a dim glow and pulses for every OpenTherm response. A failure blinks the lowest active code a number of times, then pauses for a second and repeats. Water leak flashes continuously instead.
| Blinks | Meaning | Where to look |
|---|---|---|
1 (continuous flash) | Water leak | The probe contacts are bridged. See the water leak question below. |
2 | Boiler fault | The boiler reported a fault of its own. Read Boiler OEM Fault Code and the boiler display; the THRM ONE only relays it. |
3 | No OpenTherm response | Ten seconds of silence on the bus. Check the wiring question above first, then the boiler side. |
4 | No network link | Neither Ethernet nor WiFi is up. See the network questions below. |
5 | No Home Assistant connection | The network is up but no API client has subscribed to the device state. Open Home Assistant, or check the ESPHome integration. |
6 | ESPHome internal error | Read the log over the web interface or Home Assistant, then restart the device. |
The OpenTherm wires are connected to the DC power terminals
Both terminal blocks on the THRM ONE are the same green two-pin connector, and they sit on opposite faces of the case. The OpenTherm terminals are on the left side, on the same face as the water leak port. The 5-28 V DC input is on the right side, next to the USB-C port. With the lid on and the device already mounted, it is easy to put the two OpenTherm wires from the boiler into the DC input instead.
Check this first if OpenTherm request is timing out. The Communication Error binary sensor comes on and stays on, the status LED blinks code 3, and the boiler reports no thermostat at all. Nothing else looks wrong, because the device itself is healthy.
- Check which face each pair of wires enters. OpenTherm goes to the terminals marked OT+ and OT-, on the same side as the water leak port. Power goes to the terminals marked 5-28V DC, on the same side as the USB-C and Ethernet ports.
- Read the labels on the board as well as the legend on the lid. The same markings are on the underside of the board, which you can check before the wires go in.
- Move the wires over. The polarity of the OpenTherm pair does not matter - the THRM ONE corrects it. The polarity of the DC input does matter.
- Label both cables once it works, at the wire and at the boiler. This is the mistake that repeats, and a label at each end is what stops it.
The OpenTherm terminals cannot power the device. OpenTherm carries enough energy for a basic thermostat, not for the ESP32 and the Ethernet controller. A device with the boiler wires in the DC input therefore does not start on bus power alone; if USB-C is also connected it starts normally and only the bus is silent.
Don't worry if you mixed them up, it won't damage anything. It just won't work.
The boiler says "no thermostat" during a firmware update or reset
While the ESP32 resets - during an over-the-air firmware update, or when powered off/on - the OpenTherm output is stopped, so the boiler sees thermostat. What happens next is defined by the heating system - most boilers respond by dropping to no demand, and some raise a "thermostat disconnected" or "no communication" message. The interruption should only last a few seconds.
This behaviour is intentional. During this time the microcontroller is unavailable, and is acting the same way it would if it had locked up or crashed. Sending an "idle" signal during this time instead of "disconnected" would not let the boiler fall back to its own internal methods. However, there have been reports of some heating systems taking a long time to check if the master has come back, or they need the error to be manually cleared.
- Wait for the THRM ONE to come back. The status LED breathes while it reconnects, then rests at a dim glow and pulses on every OpenTherm response.
- If the boiler stays locked out, clear the message at the boiler itself - some models need the fault acknowledged before they will fire again. Check the boiler manual for its reset procedure.
- Schedule updates for a time when the house does not depend on the heating, and check the setpoint afterwards - see the next question.
- The firmware has no restart button, so an update, a power cycle or a reflash are the only things that reboot the device. Where the update is not urgent, wait for a convenient moment.
There is no heat after a restart or a firmware update
After every reboot the control setpoint (ID1) starts at 0, which is central heating off. Home Assistant controls that value while the API link is up, so heating resumes as soon as your automation writes a setpoint again. An automation that only writes on a change - a thermostat reporting the same target all day - writes nothing after the restart, and the boiler is told 0 °C until something changes.
- Check Boiler Control Setpoint in Home Assistant. If it reads 0, that is the whole problem.
- Write a setpoint, or make the automation write it when the device comes back - a state trigger on the device becoming available is enough.
- Check that Boiler Central Heating is switched on. That switch and Boiler DHW Enabled are disabled entities by default and have to be enabled once during commissioning; see the missing-entity question below.
- If the setpoint is set and the boiler still does not fire, check Boiler Max CH Setpoint. It caps the flow temperature the boiler will accept.
Communication Error is on, but the wiring is correct
The flag means the boiler has not answered for ten seconds, after a sixty second grace period at boot. With the wiring verified, the fault is at the boiler end:
- Confirm the boiler is powered and not in a lockout of its own.
- Confirm the terminals really are the OpenTherm pair. Some boilers have separate terminals for on/off thermostats and for OpenTherm, and some label the OpenTherm pair with a different name.
- Confirm the boiler is set to accept an OpenTherm thermostat. A boiler left in on/off mode will not answer a master even when it is wired correctly.
- Check the bus with a multimeter, wires still connected: a live OpenTherm line idles at roughly 15 to 20 V and drops to about 5 V for a logic low. A flat 0 V means the boiler is not supplying the bus.
The boiler does not follow the setpoint
The THRM ONE sends the flow temperature it is told to send, and the boiler still applies its own limits. Check the following before looking for a fault:
- Boiler Max CH Setpoint (ID57) caps the flow temperature the boiler will accept. It is a number entity, and it sits at 75 °C by default.
- Many boilers keep an internal heating curve for as long as nothing asks them to do otherwise, and only hand control over once they are configured for OpenTherm or room-temperature control. The boiler manual is the reference for that setting.
- Boiler Max Modulation (ID14) throttles output; a low value keeps the water below the setpoint on a cold day.
The device does not power on
- Check the power source: 5 V over USB-C, or 5-28 V DC through the screw terminals.
- If the device is mounted, the USB-C port may be hard to reach - use the DC input, or power it over USB-C before it goes back on the boiler.
- On the DC input, check the polarity. Positive and negative must match the markings, and the screws must grip bare copper rather than insulation.
- Try a different USB power supply and a different cable, and confirm the cable is a data-capable one if you also expect a serial connection.
- Neither the Ethernet port (no PoE) nor the OpenTherm terminals can power the device.
The device does not appear when I try to provision over Bluetooth
Bluetooth provisioning only exists in the WiFi build, and only runs while the device is not connected to WiFi. With an Ethernet cable plugged in you do not need it: Home Assistant discovers the device over the network.
- Wait about 90 seconds after power-on. The Bluetooth service starts once the device has failed to join a WiFi network.
- Unplug the Ethernet cable. While Ethernet is the active link the device has no reason to be provisionable.
- Move the device close to your computer or phone. The radio is the internal antenna of the ESP32-C6, and a boiler casing full of metal shields it.
- Use the ESPHome Device Builder or web.esphome.io over Bluetooth, and make sure Home Assistant's Bluetooth integration has a working adapter or proxy in range.
- If Bluetooth still fails, provision over the USB serial connection instead (see below).
The device is not detected when I try to provision over serial (USB)
- Use a data-capable USB-C cable. Many cables are charge-only and carry no serial connection.
- Use Chrome or Edge, which support the browser serial connection used by ESPHome Web.
- Try a different USB port or cable, and press the reset contact on the board if the device was already running.
- Provisioning over serial is a one-time step: new credentials overwrite the stored ones, and there is nothing to erase first.
- Do not flash firmware from ESPHome Web. That installs a blank configuration over the firmware that ships with the device; use the Device Builder to install firmware.
The device will not connect to my WiFi network
The THRM ONE connects to 2.4 GHz WiFi only - it cannot see 5 GHz networks. If your router uses one combined name for both bands, or uses band steering, the device may fail to connect.
- Check that the 2.4 GHz band is enabled on your router.
- If your router uses band steering or a combined network name, temporarily disable band steering, or create a separate 2.4 GHz network name.
- Reprovision the device with the 2.4 GHz credentials.
- If the device cannot join at all, it starts a fallback hotspot about 90 seconds after power-on: a network named after the device, without a password. Join it and point a browser at the device to configure it.
- Ethernet is the more reliable link in a plant room, and it is used automatically whenever a cable is plugged in.
The device does not show up in Home Assistant
- Confirm the device is on the same network as your Home Assistant server - discovery relies on local multicast.
- Wait a minute or two for discovery to complete, then check for a new ESPHome device under Settings > Devices & Services.
- Open the device's IP address in a browser. If the local web interface answers, the device is on the network and only discovery is failing.
- Add the device by hand in the ESPHome integration, using its IP address or its name - the device name carries a suffix from its MAC address, so it looks like thrm-one-a1b2c3.local.
- If the device is unreachable altogether, check the network questions above and the link state of the Ethernet port.
The Ethernet link does not come up
The port is 100 Mbit only. Some switches and routers will not negotiate a 100 Mbit link on a port configured for gigabit only:
- Check the link LEDs at both ends. No light at all means no electrical link.
- Try another switch port, or a switch that supports 100 Mbit.
- Try another cable, and confirm the cable is fully seated at both ends - the jack on the case is recessed.
- If no wired link is possible, the device falls back to WiFi; provision it as described above.
I need to change the WiFi credentials or reset the device
The THRM ONE has no reset button, and no way to erase the stored network credentials from the device itself. Changing networks is a matter of provisioning it again: run Improv over USB-C or Bluetooth and enter the new credentials, which replace the old ones.
If the device is unreachable on every interface, connect it over USB-C and install the configuration again with the Device Builder. That overwrites the firmware and the stored credentials in one step.
An over-the-air update failed and the device is unresponsive
- Wait two minutes before assuming it is bricked. A failed update normally leaves the device running its previous firmware, and it reboots into that.
- Try the other network interface: an update that ran out of WiFi may complete over Ethernet, and the reverse.
- Connect the device over USB-C and install the configuration with the Device Builder - Install > Plug into this computer.
- If the browser does not see the device over USB, check the cable and port as in the serial provisioning question above.
My configuration changes have no effect
The shipped configuration imports its files from the repository, pinned to the release tag in version. A local edit to a file under esphome/core/ is therefore never compiled: the build fetches that file from Codeberg at the pinned tag and ignores your copy.
- Point the packages block at your local files, or raise version to a tag that contains your change.
- Rebuild and install, rather than restarting the device - a restart never recompiles anything.
- Confirm the running version in the device's info page in Home Assistant, or in the log at boot.
An update replaced my own configuration
The ESPHome update entity pulls the published factory firmware from the repository's releases. Installing it returns the device to the shipped configuration, so changes you made in your own YAML are not carried over. Keep your configuration in the Device Builder and install it from there after an update.
The room temperature reading is too high
The on-board NTC is a backup, not a room sensor. It sits on the board, in the warm casing next to the boiler, so it reads several degrees above the actual room temperature. It exists to keep the house from going below a safe temperature when nothing else is available, not to measure the room.
- Feed the device a real room temperature instead: write your room sensor to Control Room Temperature (ID24) from Home Assistant, which is what the boiler is told.
- If the API link drops, a 60 second interval takes the entity over and reports the NTC value, which keeps the boiler from holding a stale room temperature.
- Move the device away from uninsulated hot pipes if the reading matters to your fallback, and check the mounting as described in the setup guide.
The water leak sensor is always triggered
The input is pulled up and read active low, so bridged contacts read as a leak. The probe itself is a bare pair of contacts:
- Check the probe is dry and that its contacts are not touching each other or a metal surface.
- Check the cable where it enters the case - a pinched or damaged cable shorts the pair. Note that the water leak port shares the left face with the OpenTherm terminals.
- Unplug the probe. If the entity clears, the fault is in the cable or the probe rather than the device.
- If it still reads as a leak with nothing connected, the input is shorted; contact us.
An entity is missing in Home Assistant
The base configuration ships the most common configuration variables that are exposed by most heating systems. It does not expose all of them, and to access more, you'll need to modify the ESPHome configuration and add them yourself. See the ESPHome OpenTherm documentation for the full list.
Additionally, the switches Boiler Central Heating and Boiler DHW Enabled are hidden by default. They default to On, and are hidden so you don't disable them by accident. To see them:
- In Home Assistant, open the device's page and select Show disabled entities.
- Enable the switch you need, then confirm it is on.
Some diagnostic entities are also filed under the diagnostic category at the bottom rather than in the main list; check that section before assuming one is absent.
I still can't solve my issue